Patient Monitor with WIFI function

Place of Origin: Anhui,China (Mainland)
Brand Name: Guangli
Type: other
Packing weight: 5460g
Warranty: 18 months
Application: adult, pediatrics and neonate patients
Standard configuration: ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
Place of Origin: China(Mainland)
sample: Available
OEM: accepted
Usage: patient monitoring

inquiry

skype basketAdd to Basket  Edit

Share |

Product Description

Payment & Shipping Terms Supply Capacity
Trade Term:FOBProduction Capacity:1000sets per month
Payment Terms:L/C, WU, T/TPacking:individual packed and...
Means of Transport:Land, Ocean, AirDelivery Date:shipped in 30days...

ECG

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:  
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.  
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.    
Accuracy: Error rate < 20%          
Undetected rate < 20%  
ST section  
Scope:     ±0.8mV
Precision :  < ±0.05mV

SpO2

Detection scope:   0%-100%
Accuracy         ±1%     90%-100%                
                 ±2%      70%-89% 

NIBP 

Theory Electric oscillator  
Cuff gassing time   less than 15 seconds 
First-time gassing pressure: dynamic state 24kPa(180 mmHg) 
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg) 
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg), 
Automatic detection period: 1 minute to 240 minutes  
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min) 
Detection scope:  
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg) 
Detection accuracy  
Static pressure: ±3mmHg
Pulse rate:  ±2%

Resp

Chest impedance method or concentration of carbon dioxide at end of respiration  
Scope of chest impedance method     0 time/minute – 100 minutes/minute  
Precision of chest impedance method  time/minute  
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby) 
Detection precision of respiration rate: ±1 time/minute 

Temp

Single/double path  
Type:    Vascular/surface temperature  
Scope:    20℃~50℃ 
Accuracy:  ±0.2℃

Invasive blood pressure (optional)

Single/double path  
Type: direct and continuous detection  
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC) 
Accuracy of sensor: ±2%Isolation voltage: 4 kV

patient monitor,patients monitoring system,remote patient monitoring,medical monitor,medical grade monitoring,vital signs monitor,wireless monitoring

 Patient Monitor with WIFI function

Patient Monitor with WIFI function

Patient Monitor with WIFI function

Patient Monitor with WIFI function

Category: Medical hospital equipment Patient Monitoring System

Related Category: Medical hospital Diagnosis equipment  Medical therapy equipments and Surgical Equipments  Hospital equipment and machine 


Contact Us
Welcome to our website !